铭品电缆集团有限公司-亚博vip88

亚博yabovip的产品展示products 当前位置:亚博vip88-亚博yabovip > 亚博yabovip的产品展示 > 电力电缆

一、用途  use


本产品适用不于交流50hz,额定电压0. 6/1kv的线路中,供输配电能之用。
the cable is used as power distribution and transimssion line at rated voltage 0.6/1kv which can be fixed installed.


二、使用特性  using property


(1)电缆导体的最高额定温度为70°c
(2)短路时(最长持续时间不超过5s)电缆导体的最高温度不超过160°c 。
(3)敷设电缆时的环境温度不低于0°c,最小弯曲半径应不小于电缆外径的10倍。

1)the long time working temperature of cable should not be highter than 70°c.
(2) short (the longest duration of no more than 5s) conductor temperature does not exceed 160°c.
(3) ambient temperature when laying cable is not below 0℃,the minimum bend radius should be 10 times the cable diameter is not small.


三、型号、名称和使用范围(见表1)  model, name and application (see table 1 )



型号 model 名称 name 适用范围 main application

vv

vlv


聚氯乙烯绝缘聚氯乙烯护套电力电缆

pvc insulated pvc sheathed power cable


敷设在室内、隧道及管道中,电缆不能承受压力和机械外力作用。

for laying indoors,tunnels and pipelines,cable can not withstand the pressure and mechanical force.

vv22

vlv22


聚氯乙烯绝缘钢带铠装聚氯乙烯护套电力电缆

pvc insulated steel tape amoured pvc sheathed power cable


敷设在室内、隧道及直埋土壤中,电缆能承受压力和机械外力作用。

laying indoors,in tunnels and buried in soil,the cable can  withstand the pressure and mechanical force.


vv32

vlv32


聚氧乙烯绝缘细钢丝铠装聚氯乙烯护套电力电缆

pvc insulated fine steel tape amoured pvc sheathed power cable


敷设在室内、矿井中,水中,电缆能承受相当的拉力。

for laying indoors,mines,water,able to withstand considerable tension.

vv42

vlv42

聚氧乙烯绝缘粗钢丝铠装聚氯乙烯护套电力电缆

pvc insulated steel wire amoured pvc sheathed power cable

敷设在竖井,水下等垂直场合,能承受相当的轴向拉力。

for laying indoors,mines,water,able to withstand considerable tension.

zr-vv

zr-vlv

聚氯乙烯绝缘聚氯乙烯护套阻燃电力电缆

pvc insulated pvc sheathed flame retardant power cable

敷设在室内、隧道及管道中,电缆不能承受压力和机械外力作用。

for laying indoors,mines,water,able to withstand considerable tension.

zr-vv22

zr-vlv22

聚氯乙烯绝缘钢带铠装聚氯乙烯护套阻燃电力电缆

pvc insulated steel tape armoured pvc sheathed flame retardant power cable

敷设在室内、隧道及直埋土壤中,电缆能承受压力和其他外力作用。

for laying indoors,mines,water,able to withstand considerable tension.

zr-vv32

zr-vlv32

聚氧乙烯绝缘细钢丝铠装聚氯乙烯护套阻燃电力电缆

pvc insulated steel tape armoured pvc sheathed flame retardant power cable

敷设在室内、矿井中,水中,电缆能承受相当的拉力。

for laying indoors,mines,water,able to withstand considerable tension.

zr-vv42

zr-vlv42

聚氧乙烯绝缘粗钢丝铠装聚氯乙烯护套阻燃电力电缆

pvc insulated steel wire armoured pvc sheathed flame retardant power cable

敷设在竖井,水下等垂直场合,能承受相当的轴向拉力。

laying in the shaft,underwater vertical occasions,able to withstand considerable axial tension.


四、电缆结构尺寸  construction

vv,vlv,zrvv,zrvlv

0.6/1kv pvc 绝缘 pvc 护套阻燃或非阻燃电力电缆《参数列表》
0.6/1 kv pvc insutaled pvc sheathed flame retardant and non-flame retardant power cable《table》


vv22vlv22zrvv22zrvlv22

0.6/1kv pvc 绝缘钢带铠装 pvc 护套阻燃或非阻燃电力电缆《参数列表》
0.6/1 kv pvc insulated steel armoured pvc sheathed flame retardant and non-flame retarand power cable《table


vv72vlv72zrvv72zrvlv72 -0.6/1kv pvc 绝缘钢丝铠装 pvc 护套阻燃或非阻燃电力电缆《参数列表》

vv32,vlv32,zrvv32,zrvlv32 -0.6/1 kv pvc 绝缘钢丝铠装 pvc 护套阻燃或非阻燃电力电缆《参数列表》

vv32,vlv32,zrvlv32,zrvlv32 -0.6/1 kv pvc 绝缘钢丝铠装 pvc 护套阻燃或非阻燃电力电缆《参数列表》


五、电缆运行敷设条件  installation



电缆敷设
1、敷设时电缆温度不低于0°c,环境温度低于0℃时,应对电缆进行预热。
2、敷设的弯曲半径不小于电缆外径的8倍。
3、电缆敷设后,应经受以直流耐压试验,时间15分钟,试验电压3.5kv。
在空气中敷设
1、单芯电缆平行敷设时中心距离:185mm2及以下为电缆直径的2倍240mm2及以上为90mm。
2、周围环境温度:30°c。
3、导电线芯最高允许温度:70°c 。
4、不同环境温度下载流量的校正系数:
环境温度 20℃ 25℃ 35℃ 40℃ 45℃
校正系数 1.12 1.06 0.94 0.87 0.79

直埋敷设 1、单芯电缆不接触敷设时,中心距离为电缆直径的2倍。
2、周围环境温度:25°c。
3、导电线芯最高允许温度:70°c。
4、土壤热阻系数:1.0°c.m/w。
5、直埋深度:≥0.7m。
6、不同环境温度下载流量的校正系数:
环境温度
15 20 30 35
校正系数
1.11 1.05 0.94 0.88


短路容量:

导电线芯短路时允许最高温度 最高允许的短路电流
130℃ i=94s/√1ta

installation
1.the installation temperature should not over 20°c,if the ambient temperature is lower than 0°c,the cable should be preheated.
2.the bending radius of cable should not less than 8 times.
3.after installantion,the cable should withstand voltage test for 15 min.3.5kv d.c.
in air
1.as the single core cable laying in parallel,the distance between the cableos center is tines (for cables, which cross sectional area of conductor ≤185mm2) and 90mm (for cables,which cross sectional area of conductor ≤240mm2).
2.ambient temperature:40°c.
3.max.temperature of conductor:70°c.
4 .rating factors of current rating for ambient temperature:
air temperature 20℃
25℃ 35℃ 40℃ 45℃
rating factors 1.12 1.06 0.94 0.87 0.79

direct in ground
1.when the single core cables are installed separately, the distance between the cable os center is 2 times of the cable diameter.
2.ambient temperature:25°c.
3.mabient temperature of conductor:70°c.
4.soil themour resistivity:1.0°c.m/w.
5.depth:≥0.7m.
6.rating factors under different ambient temperature:
air temperature
15 20 30 35
rating factors
1.11 1.05 0.94 0.88

short ciruit ratings:
max,temperature at short circuit max,short circuit current
130℃
i=94s/√1ta



六、电缆载流量   rating fators


vv、zrvv
0.6/1kv 铜导体 pvc 绝缘 pvc 护套阻燃和非阻燃电力电缆在空气中敷设长期连续负荷允许载流量
0.6/1kv copper conductor pvc insulated pvc sheathed flame retardant & non-flame ratardant power cable installed in air for long term continuosly load
vv22、 zrvv22
0.6/1kv 铜导体 pvc 绝缘 pvc 护套阻燃或非阻燃电力电缆在直埋敷设长期连续负荷允许载流量
0.6/1kv copper conductor pvc insulated pvc sheathed flame retardant & non-flame ratardant power cable installed direct in ground for long term continuously load


导线标称斜面
长期连续负荷允许截
无铠装
铠装
单芯
双芯
五芯 单芯

三芯 五芯

2根

3根 四芯
(4 1)芯 2根 3根
四芯 (4 1)芯
〇〇

〇〇〇 (3 1)芯
(3 2)芯 〇〇

〇〇〇 (3 1)芯 (3 2)
1.5 28 23 26 20

28 23 26


2.5 36 30 33 26

36 30 33


4
47 39 44 37 30 31 47 39 44 38 31 32
6 60 59 56 44 37 38 60 49 56 45 38 39
10 83 68 77 61 53 54 83 68 77 62 54 55
16 109 89 101 82 69 70 109 89 101 84 70 71
25
138 113 128 104 89 91 138 113 128 106 91 91
35 173 142 161 127 109 111 173 142 161 130 111 112
50 207 170 193 155 132 135 207 170 193 158 135 137
70 264 216 246 190 167 170 264 216 246 194 170 173
95 322 264 299 242 213 217 322 264 299 247 217 221
120 374 307 348 282 242 247 374 307 348 288 264 250
150 431 353 401 322 282 288 431 353 401 328 287 290
185 495 406 460 368 322 328 495 406 460 378 327 330
240 587 481 546
385 393 587 481 546
392 398
300 673 552 626
431 440 673 552 626
439 445
400 794 652 738


794 652 738


500 920 754 856


920 754 856


630 1058 868 984


1058 868 984


800 1219 1001 1134


1219 1001 1134




vlv、zrvlv
0.6/1kv 铝导体 pvc 绝缘 pvc 护套阻燃和非阻燃电力电缆在空气中敷设长期连续负荷允许载流量
0.6/1 kv aluminum conductor pvc insulated pvc sheathed retardant & non-flame ratardant power cable installed inairfor long term continuosly load

vlv22、zrvlv22
载流量 rating fators 0.6/1kv 铝导体 pvc 绝缘 pvc 护套阻燃或非阻燃电力直埋敷设长期连续负荷允许载流量
0.6/1kv aluminum conductor pvc insulated pvc sheathed flame retardant & non-flame ratardant power cable installed direct in ground for long term continuously load


导线标称斜面
长期连续负荷允许截
无铠装
铠装
单芯
双芯
五芯 单芯

三芯 五芯

2根

3根 四芯
(4 1)芯 2根 3根
四芯 (4 1)芯
〇〇

〇〇〇 (3 1)芯
(3 2)芯 〇〇

〇〇〇 (3 1)芯 (3 2)
2.5 28 23 26 21 17 17 28 23 26


4 36 30 34 28 23 23 36 30 34 28 23 23
6 47 40 45 37 30 31 47 40 45 37 30 31
10 60 52 59 48 40 41 60 52 59 48 40 41
16 84 69 78 63 54 55 84 69 78 63 54 55
25 110 90 102 81 69 70 110 90 102 81 69 70
35 132 108 123 99 85 87 132 108 123 99 85 87
50 161 132 150 121 104 106 161 132 150 121 104 106
70 201 165 187 150 132 135 201 165 187 150 132 135
95 247 203 230 190 161 164 247 203 230 190 161 164
120 288 236 268 219 190 194 288 236 268 219 190 194
150 334 274 311 247 219 223 334 274 311 247 219 223
185 385 316 358 288 247 252 385 316 358 288 247 252
240 454 372 422
299 305 454 372 422
299 305
300 523 429 486
399 346 523 429 486
399 346
400 621 509 578


621 509 578


500 725 595 674


725 595 674


630 851 698 791


851 698 791


800 989 811 920


989 811 920


1000 1080 885 1104


1080 885 1104



上一篇:聚氯乙烯绝缘护套耐火电力电缆下一篇:没有了!